Eaton
XTCE040D00AD
Definite Purpose (DP) contactor (DOL (Direct On Line) / FVNR (Full-Voltage Non-Rv.)) - Eaton / Cutler-Hammer (XT IEC power control) - 3-poles (3P) - Rated current 40A (AC-3) - Rated power 18.5kW (380/440Vac; AC-3; IEC; 50/60Hz) / 30HP (3-phase; UL/CSA; 460Vac) - Control coil voltage 110Vdc-130Vdc - Screw connection - Frame D - DIN rail mounting
Brand
SKU
XTCE040D00AD
Please add this item to cart to request a quote.
Eaton / Cutler-Hammer - XT IEC power control (XTCE)XTCE040D00AD
Description
Definite Purpose (DP) contactor (DOL (Direct On Line) / FVNR (Full-Voltage Non-Rv.)) - Eaton / Cutler-Hammer (XT IEC power control) - 3-poles (3P) - Rated current 40A (AC-3) - Rated power 18.5kW (380/440Vac; AC-3; IEC; 50/60Hz) / 30HP (3-phase; UL/CSA; 460Vac) - Control coil voltage 110Vdc-130Vdc - Screw connection - Frame D - DIN rail mounting
Specifications
Primary brand
Eaton
Secondary brand
Cutler-Hammer
Main function
Contactor
Product series / family name
XT IEC power control
Sub-range name
XTCE
Functions
Definite Purpose (DP) contactor
Rated current
40A (AC-3)
60A (AC-1)
60A (AC-1)
Rated active power (kW)
12.5kW (220/230Vac; AC-3; IEC; 50/60Hz)
18.5kW (380/440Vac; AC-3; IEC; 50/60Hz)
24kW (415Vac; AC-3; IEC; 50/60Hz)
23kW (660/690Vac; AC-3; IEC; 50/60Hz)
18.5kW (380/440Vac; AC-3; IEC; 50/60Hz)
24kW (415Vac; AC-3; IEC; 50/60Hz)
23kW (660/690Vac; AC-3; IEC; 50/60Hz)
Rated reactive power (kVAr)
11kVAr (Individual Compensation; 230Vac)
20.5kVAr (Individual Compensation; 400/420/440Vac)
24.5kVAr (Individual Compensation; 525Vac)
32kVAr (Individual Compensation; 690Vac)
13kVAr (Group Compensation with reactor; 230Vac)
25kVAr (Group Compensation with reactor; 400/420/440Vac)
30kVAr (Group Compensation with reactor; 525Vac)
40kVAr (Group Compensation with reactor; 690Vac)
20.5kVAr (Individual Compensation; 400/420/440Vac)
24.5kVAr (Individual Compensation; 525Vac)
32kVAr (Individual Compensation; 690Vac)
13kVAr (Group Compensation with reactor; 230Vac)
25kVAr (Group Compensation with reactor; 400/420/440Vac)
30kVAr (Group Compensation with reactor; 525Vac)
40kVAr (Group Compensation with reactor; 690Vac)
Rated power (HP)
3HP (Single-phase; UL/CSA; 115Vac)
5HP (Single-phase; UL/CSA; 200Vac)
7.5HP / 7-1/2HP (Single-phase; UL/CSA; 230Vac)
10HP (3-phase; UL/CSA; 200Vac)
15HP (3-phase; UL/CSA; 230Vac)
30HP (3-phase; UL/CSA; 460Vac)
40HP (3-phase; UL/CSA; 575Vac)
5HP (Single-phase; UL/CSA; 200Vac)
7.5HP / 7-1/2HP (Single-phase; UL/CSA; 230Vac)
10HP (3-phase; UL/CSA; 200Vac)
15HP (3-phase; UL/CSA; 230Vac)
30HP (3-phase; UL/CSA; 460Vac)
40HP (3-phase; UL/CSA; 575Vac)
Rated operating voltage (Ue)
690 V
Rated insulation voltage (Ui)
690 V
Connection type
Screw connection
Poles
3 Pole(s)
Control Voltage (DC)
110Vdc-130Vdc
Net Width (mm)
55 mm
Mounting mode
DIN rail
Number of Normally Open (NO) circuits
3 NO Pole(s)
Mechanical durability (at no load)
10 000 000 operations
Application type
DOL (Direct On Line)
FVNR (Full-Voltage Non-Rv.)
FVNR (Full-Voltage Non-Rv.)
Manufacturer product status
Commercialized
Compliant with standard(s)
IEC/EN 60947
VDE 0660
UL
CSA
RoHS
CCC
VDE 0660
UL
CSA
RoHS
CCC
Operating rate
(Electrical; AC-3; 400Vac) 800 Cycles/hour
(Electrical; AC-1; 400Vac) 800 Cycles/hour
(Mechanical) 5000 Cycles/hour
(Electrical; AC-1; 400Vac) 800 Cycles/hour
(Mechanical) 5000 Cycles/hour
Degree of pollution
3
Related Documents
Name | Last Update | Language |
---|---|---|
Eaton - Motor Control and Protection - Catalogue.pdf | 27 Nov 2018 | English (US) |