Eaton
S811+V72N3S
Open Reduced Voltage Motor Starter (RVMS) / Soft-starter (SS) with digital interface module (DIM) - Eaton / Cutler-Hammer (S811+) - Rated input voltage (3-phase (3P)) 200Vac-600Vac - Rated output current 720A (Standard duty) - Rated power 400kW (380-400V; Standard duty; 15s ramp; 300% current limit at 40°C; Inline connection; 50Hz) / 600HP (460V; Standard duty; 15s ramp; 300% current limit at 40°C; Inline connection; 60Hz; 1.0SF) - Control voltage 24Vdc - Frame size V - with Internal bypass - with Lug kits
Brand
SKU
S811+V72N3S
Please add this item to cart to request a quote.
Eaton - S811+S811+V72N3S
Description
Open Reduced Voltage Motor Starter (RVMS) / Soft-starter (SS) with digital interface module (DIM) - Eaton / Cutler-Hammer (S811+) - Rated input voltage (3-phase (3P)) 200Vac-600Vac - Rated output current 720A (Standard duty) - Rated power 400kW (380-400V; Standard duty; 15s ramp; 300% current limit at 40°C; Inline connection; 50Hz) / 600HP (460V; Standard duty; 15s ramp; 300% current limit at 40°C; Inline connection; 60Hz; 1.0SF) - Control voltage 24Vdc - Frame size V - with Internal bypass - with Lug kits
Specifications
Primary brand
Eaton
Secondary brand
Cutler-Hammer
Main function
Soft starter
Product series / family name
S811+
Network frequency
(input) 47-63 Hz
Functions
Open Reduced Voltage Motor Starter (RVMS) / Soft-starter (SS) with digital interface module (DIM)
Lug kits
Lug kits
Supply voltage (AC)
200Vac-600Vac
Type of network
3-phase input (3P)
Rated current
720A (Standard duty; 15s ramp; 300% current limit at 40°C; Inline connection)
480A (Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection)
480A (Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection)
Rated active power (kW)
400kW (380-400V; Standard duty; 15s ramp; 300% current limit at 40°C; Inline connection; 50Hz)
220kW (230V; Standard duty; 15s ramp; 300% current limit at 40°C; Inline connection; 50Hz)
450kW (440V; Standard duty; 15s ramp; 300% current limit at 40°C; Inline connection; 50Hz)
147kW (230V; Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection; 50Hz)
257kW (380-400V; Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection; 50Hz)
295kW (440V; Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection; 50Hz)
220kW (230V; Standard duty; 15s ramp; 300% current limit at 40°C; Inline connection; 50Hz)
450kW (440V; Standard duty; 15s ramp; 300% current limit at 40°C; Inline connection; 50Hz)
147kW (230V; Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection; 50Hz)
257kW (380-400V; Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection; 50Hz)
295kW (440V; Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection; 50Hz)
Rated power (HP)
600HP (460V; Standard duty; 15s ramp; 300% current limit at 40°C; Inline connection; 60Hz; 1.0SF)
500HP (460V; Standard duty; 15s ramp; 300% current limit at 40°C; Inline connection; 60Hz; 1.15SF)
300HP (230V; Standard duty; 15s ramp; 300% current limit at 40°C; Inline connection; 60Hz; 1.0SF)
250HP (230V; Standard duty; 15s ramp; 300% current limit at 40°C; Inline connection; 60Hz; 1.15SF)
700HP (575-690V; Standard duty; 15s ramp; 300% current limit at 40°C; Inline connection; 60Hz; 1.0SF)
600HP (575-690V; Standard duty; 15s ramp; 300% current limit at 40°C; Inline connection; 60Hz; 1.15SF)
150HP (200V; Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection; 60Hz; 1.0SF)
150HP (200V; Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection; 60Hz; 1.15SF)
200HP (230V; Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection; 60Hz; 1.0SF)
150HP (230V; Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection; 60Hz; 1.15SF)
400HP (460V; Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection; 60Hz; 1.0SF)
350HP (460V; Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection; 60Hz; 1.15SF)
500HP (575-690V; Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection; 60Hz; 1.0SF)
450HP (575-690V; Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection; 60Hz; 1.15SF)
500HP (460V; Standard duty; 15s ramp; 300% current limit at 40°C; Inline connection; 60Hz; 1.15SF)
300HP (230V; Standard duty; 15s ramp; 300% current limit at 40°C; Inline connection; 60Hz; 1.0SF)
250HP (230V; Standard duty; 15s ramp; 300% current limit at 40°C; Inline connection; 60Hz; 1.15SF)
700HP (575-690V; Standard duty; 15s ramp; 300% current limit at 40°C; Inline connection; 60Hz; 1.0SF)
600HP (575-690V; Standard duty; 15s ramp; 300% current limit at 40°C; Inline connection; 60Hz; 1.15SF)
150HP (200V; Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection; 60Hz; 1.0SF)
150HP (200V; Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection; 60Hz; 1.15SF)
200HP (230V; Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection; 60Hz; 1.0SF)
150HP (230V; Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection; 60Hz; 1.15SF)
400HP (460V; Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection; 60Hz; 1.0SF)
350HP (460V; Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection; 60Hz; 1.15SF)
500HP (575-690V; Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection; 60Hz; 1.0SF)
450HP (575-690V; Severe duty; 30s ramp; 450% current limit at 50°C; Inline connection; 60Hz; 1.15SF)
Control Voltage (DC)
24Vdc
Protection functions
Motor overload
Short-circuit
External E-Stop
External trip
Fault warning functionality
External warning
Custom fault / Warning auxiliary relays
Motor power
Start delay
Jam
Stall
Pole over temperature
Phase loss
Phase imbalance
Reset mode
Phase reversal
Shorted SCR detection
Open SCR detection
Low current
Low voltage
High voltage
Short-circuit
External E-Stop
External trip
Fault warning functionality
External warning
Custom fault / Warning auxiliary relays
Motor power
Start delay
Jam
Stall
Pole over temperature
Phase loss
Phase imbalance
Reset mode
Phase reversal
Shorted SCR detection
Open SCR detection
Low current
Low voltage
High voltage
Net Height (mm)
420.8 mm
Net Width (mm)
280.6 mm
Net Depth (mm)
187.8 mm
Ambient air temperature for operation
-30...+50 °C
Ambient air temperature for storage
-50...+70 °C
Technology used in component
Internal bypass
Manufacturer product status
Commercialized
Compliant with standard(s)
IEC 60947-4-2
EN 60947-4-2
UL listed (NMFT-E202571)
UL recognized (NMFT2)
CE marked
CSA certified (3211 06)
CSA elevator (2411 01)
EN 60947-4-2
UL listed (NMFT-E202571)
UL recognized (NMFT2)
CE marked
CSA certified (3211 06)
CSA elevator (2411 01)
Benefits
Communication capabilities with various protocols
The Digital Interface Module (DIM) provides an intuitive easy-to-use human interface with powerful configuration capabilities to maximize system performance
Door or device mounted DIM enables users to safely configure; commission; monitor and troubleshoot the system at the electrical panel without opening the enclosure door
System operating parameters can be monitored enterprise-wide through a communications network
Run internal bypass mode greatly reduces internal heating created by the greater power dissipation in the SCRs
Internal solid-state overload protection provides accurate current measurement and trip settings
Internal run bypass contactors and overload protection eliminate the need for additional devices
Variable ramp times and torque control settings provide unlimited starting configurations allowing for maximum application flexibility
Kick-start feature enables soft starting of high friction loads
Soft stop control for applications where an abrupt stop of the load is not acceptable
Six SCRs control all three motor phases; providing smooth acceleration and deceleration performance
Soft acceleration and deceleration reduces wear on belts; gears; chains; clutches; shafts and bearings
Reduce the peak inrush current’s stress on the power system
Manage peak starting torque to diminish mechanical system wear and damage
Removable and lockable control terminal block reduces maintenance costs
The Digital Interface Module (DIM) provides an intuitive easy-to-use human interface with powerful configuration capabilities to maximize system performance
Door or device mounted DIM enables users to safely configure; commission; monitor and troubleshoot the system at the electrical panel without opening the enclosure door
System operating parameters can be monitored enterprise-wide through a communications network
Run internal bypass mode greatly reduces internal heating created by the greater power dissipation in the SCRs
Internal solid-state overload protection provides accurate current measurement and trip settings
Internal run bypass contactors and overload protection eliminate the need for additional devices
Variable ramp times and torque control settings provide unlimited starting configurations allowing for maximum application flexibility
Kick-start feature enables soft starting of high friction loads
Soft stop control for applications where an abrupt stop of the load is not acceptable
Six SCRs control all three motor phases; providing smooth acceleration and deceleration performance
Soft acceleration and deceleration reduces wear on belts; gears; chains; clutches; shafts and bearings
Reduce the peak inrush current’s stress on the power system
Manage peak starting torque to diminish mechanical system wear and damage
Removable and lockable control terminal block reduces maintenance costs
Net weight
46.8 kg
Degree of pollution
3
Related Documents
Name | Last Update | Language |
---|---|---|
Eaton - S611 S811 S801 DS7 S701 TL - Catalogue.pdf | 23 Jun 2020 | English (US) |