Eaton
EGS9D6JB1200B10000
Enclosed Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter with start-stop controls; speed pot & HOA switch - Eaton / Cutler-Hammer (PowerXL DG1) - Rated input voltage (Single-phase (2P)) 230Vac - Rated output current 9.6A (Low overload IL) - Rated power 2.2kW (Low overload IL) / 3HP (Low overload IL) - Frame size 2 - UL type 1 / NEMA 1 - with RS-485 / Ethernet/IP / Modbus TCP / Modbus RTU / BACnet communication capability - with conformal coated PCB - with Brake chopper + Non-bypass light kit
Brand
SKU
EGS9D6JB1200B10000
Please add this item to cart to request a quote.
Eaton - PowerXL DG1EGS9D6JB1200B10000
Description
Enclosed Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter with start-stop controls; speed pot & HOA switch - Eaton / Cutler-Hammer (PowerXL DG1) - Rated input voltage (Single-phase (2P)) 230Vac - Rated output current 9.6A (Low overload IL) - Rated power 2.2kW (Low overload IL) / 3HP (Low overload IL) - Frame size 2 - UL type 1 / NEMA 1 - with RS-485 / Ethernet/IP / Modbus TCP / Modbus RTU / BACnet communication capability - with conformal coated PCB - with Brake chopper + Non-bypass light kit
Specifications
Primary brand
Eaton
Secondary brand
Cutler-Hammer
Main function
Variable Speed / Frequency Drive (VSD/VFD) / Inverter
Product series / family name
PowerXL
Sub-range name
DG1
Network frequency
(input) 45-66 Hz
(output) 0-400 Hz
(output) 0-400 Hz
Functions
Enclosed Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter with start-stop controls; speed pot & HOA switch
Brake chopper
Non-bypass light kit
Circuit breaker power disconnect
Non-bypass light (white = Power ON; green = RUN; red = FAULT)
Brake chopper
Non-bypass light kit
Circuit breaker power disconnect
Non-bypass light (white = Power ON; green = RUN; red = FAULT)
Supply voltage (AC)
230Vac
Type of network
Single-phase input (2P)
Rated current
9.6A (Low overload IL)
Rated active power (kW)
2.2kW (Low overload IL)
Rated power (HP)
3HP (Low overload IL)
Protection functions
Overvoltage
Overvoltage trip limit
Undervoltage
Undervoltage trip limit
Earth fault
Input phase supervision
Motor phase supervision
Overcurrent
Unit overtemperature
Motor overload
Motor stall
Motor underload
DC bus overvoltage control
Short-circuit
Surge protection
Overvoltage trip limit
Undervoltage
Undervoltage trip limit
Earth fault
Input phase supervision
Motor phase supervision
Overcurrent
Unit overtemperature
Motor overload
Motor stall
Motor underload
DC bus overvoltage control
Short-circuit
Surge protection
Communication protocol
RS-485
Ethernet/IP
Modbus TCP
Modbus RTU
BACnet
Ethernet/IP
Modbus TCP
Modbus RTU
BACnet
Operating mode
Frequency control
Speed control
Open-loop speed control
Open-loop torque control
Speed control
Open-loop speed control
Open-loop torque control
Digital inputs
1 x digital input (FWD)
1 x digital input (REV)
1 x digital input (External Fault)
1 x digital input (Fault Reset)
1 x digital input (Preset Speed B0)
1 x digital input (Preset Speed B1)
1 x digital input (Emergency Stop TI-)
1 x digital input (Force Remote TI+)
1 x digital input (REV)
1 x digital input (External Fault)
1 x digital input (Fault Reset)
1 x digital input (Preset Speed B0)
1 x digital input (Preset Speed B1)
1 x digital input (Emergency Stop TI-)
1 x digital input (Force Remote TI+)
Digital outputs
1 x digital output (READY)
2 x digital outputs (SPDT Single Pole Double Throw contact type)
1 x digital output (NO contact type)
2 x digital outputs (SPDT Single Pole Double Throw contact type)
1 x digital output (NO contact type)
Analog inputs
2 x analog inputs (4-20mA / 0-10V DC)
Analog outputs
1 x analog output (Output Frequency; 4-20mA)
1 x analog output (Motor Current; 4-20mA)
1 x analog output (Motor Current; 4-20mA)
Degree of protection
UL type 1
NEMA 1
NEMA 1
Ambient air temperature for operation
-10...+40 °C
Ambient air temperature for storage
-40...+70 °C
Chemical resistance
conformal coated PCB
Application type
General-purpose drive
Manufacturer product status
Commercialized
Compliant with standard(s)
IEC 60068-2-60
IEC 60721-3-3
EN 61800-3
UL 508C
EN 61800-5-1
IEC 60721-3-3
EN 61800-3
UL 508C
EN 61800-5-1
Benefits
Dual rated for both constant torque (CT) / high overload (IH) and variable torque (VT) / low overload applications
Optional Brake Chopper for external braking applications
Available circuit breaker; motor circuit protector; fused disconnect; isolation fusing and surge protection device options to provide input power protection
Optional 3% input and output reactors provide a reduction in voltage and current harmonics on both line and load side
Bypass options include a standard three-contactor design and a reduced voltage soft starter design
Output contactor option provides a means for positive disconnection of the drive output from the motor terminals
MotoRX and dV/dt filter options are used to reduce transients voltages at the motor terminals
Customizable cover control options
Padlockable disconnect
Optional Brake Chopper for external braking applications
Available circuit breaker; motor circuit protector; fused disconnect; isolation fusing and surge protection device options to provide input power protection
Optional 3% input and output reactors provide a reduction in voltage and current harmonics on both line and load side
Bypass options include a standard three-contactor design and a reduced voltage soft starter design
Output contactor option provides a means for positive disconnection of the drive output from the motor terminals
MotoRX and dV/dt filter options are used to reduce transients voltages at the motor terminals
Customizable cover control options
Padlockable disconnect
Degree of pollution
2
Related Documents
Name | Last Update | Language |
---|---|---|
Eaton - PowerXL M-Max SVX H-Max SPX EGF CFX HCX CPX RGX LCX SPA SPN SPI - Catalogue.pdf | 23 Jun 2020 | English (US) |