Eaton
DS7-340SX032N0-L
Reduced Voltage Motor Starter (RVMS) / Soft-starter (SS) for low temperatures - Eaton / Cutler-Hammer (DS7) - Rated input voltage (3-phase (3P)) 380Vac-480Vac - Rated output current 32A (Rated operational current) - Rated power 15kW (400V; 10s ramp; 300% current limit at 40°C) / 20HP (480V; 10s ramp; 300% current limit at 40°C) - Control voltage 24Vac / 24Vdc - Frame size 2 - IP20 - with Internal bypass
Brand
SKU
DS7-340SX032N0-L
Please add this item to cart to request a quote.
Eaton - DS7DS7-340SX032N0-L
Description
Reduced Voltage Motor Starter (RVMS) / Soft-starter (SS) for low temperatures - Eaton / Cutler-Hammer (DS7) - Rated input voltage (3-phase (3P)) 380Vac-480Vac - Rated output current 32A (Rated operational current) - Rated power 15kW (400V; 10s ramp; 300% current limit at 40°C) / 20HP (480V; 10s ramp; 300% current limit at 40°C) - Control voltage 24Vac / 24Vdc - Frame size 2 - IP20 - with Internal bypass
Specifications
Primary brand
Eaton
Secondary brand
Cutler-Hammer
Main function
Soft starter
Product series / family name
DS7
Network frequency
(input) 50-60 Hz
Functions
Reduced Voltage Motor Starter (RVMS) / Soft-starter (SS) for low temperatures
Supply voltage (AC)
380Vac-480Vac
Type of network
3-phase input (3P)
Rated current
32A (Rated operational current)
32A (10s ramp; 300% current limit at 40°C according to NEMA rating)
22A (10s ramp; 400% current limit at 40°C according to NEMA rating)
32A (10s ramp; 300% current limit at 40°C according to IEC 60947-4-2 rating)
24A (10s ramp; 400% current limit at 40°C according to IEC 60947-4-2 rating)
32A (10s ramp; 300% current limit at 40°C according to NEMA rating)
22A (10s ramp; 400% current limit at 40°C according to NEMA rating)
32A (10s ramp; 300% current limit at 40°C according to IEC 60947-4-2 rating)
24A (10s ramp; 400% current limit at 40°C according to IEC 60947-4-2 rating)
Rated active power (kW)
15kW (400V; 10s ramp; 300% current limit at 40°C)
7.5kW (230V; 10s ramp; 300% current limit at 40°C)
5.5kW (230V; 10s ramp; 400% current limit at 40°C)
11kW (400V; 10s ramp; 400% current limit at 40°C)
7.5kW (230V; 10s ramp; 300% current limit at 40°C)
5.5kW (230V; 10s ramp; 400% current limit at 40°C)
11kW (400V; 10s ramp; 400% current limit at 40°C)
Rated power (HP)
20HP (480V; 10s ramp; 300% current limit at 40°C)
7.5HP (200V; 10s ramp; 300% current limit at 40°C)
10HP (230V; 10s ramp; 300% current limit at 40°C)
5HP (200V; 10s ramp; 400% current limit at 40°C)
7.5HP (230V; 10s ramp; 400% current limit at 40°C)
15HP (480V; 10s ramp; 400% current limit at 40°C)
7.5HP (200V; 10s ramp; 300% current limit at 40°C)
10HP (230V; 10s ramp; 300% current limit at 40°C)
5HP (200V; 10s ramp; 400% current limit at 40°C)
7.5HP (230V; 10s ramp; 400% current limit at 40°C)
15HP (480V; 10s ramp; 400% current limit at 40°C)
Control Voltage (AC)
24Vac
Control Voltage (DC)
24Vdc
Net Height (mm)
150 mm
Net Width (mm)
45 mm
Net Depth (mm)
118 mm
Degree of protection
IP20
Ambient air temperature for operation
0...+40 °C
Ambient air temperature for storage
-25...+55 °C
Technology used in component
Internal bypass
Manufacturer product status
Commercialized
Compliant with standard(s)
IEC 60947-4-2
EN 60947-4-2
GB14048.6
UL508
CSA-C22.2 No 0-M91
CSA-C22.2 No 14-05
CE marked
EN 60947-4-2
GB14048.6
UL508
CSA-C22.2 No 0-M91
CSA-C22.2 No 14-05
CE marked
Benefits
Run bypass mode greatly reduces internal heating created by the power dissipation across the SCRs
Less heat minimizes enclosure size and cooling requirements and maximizes the life of all devices in the enclosure
LED displays device status and provides fault indication
Variable ramp times and voltage control (torque control) settings provide unlimited starting configurations allowing for maximum application flexibility
Less heat minimizes enclosure size and cooling requirements and maximizes the life of all devices in the enclosure
LED displays device status and provides fault indication
Variable ramp times and voltage control (torque control) settings provide unlimited starting configurations allowing for maximum application flexibility
Net weight
0.4 kg
Related Documents
Name | Last Update | Language |
---|---|---|
Eaton - S611 S811 S801 DS7 S701 TL - Catalogue.pdf | 23 Jun 2020 | English (US) |