Eaton
DG1-34072FN-C21C
Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter - Eaton / Cutler-Hammer (PowerXL DG1) - Rated input voltage (3-phase (3P)) 380Vac-500Vac - Rated output current 87A (Low overload IL) - Rated power 45kW (Low overload IL; 400Vac; 50Hz) / 60HP (Low overload IL; 460V; 60Hz) - Frame size FR4 - IP21 - with EMC filter category C2 + DC choke - with Ethernet/IP / Modbus TCP / Modbus RTU / BACnet communication capability - with conformal coated PCB
Brand
SKU
DG1-34072FN-C21C
Please add this item to cart to request a quote.
Eaton - PowerXL DG1DG1-34072FN-C21C
Description
Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter - Eaton / Cutler-Hammer (PowerXL DG1) - Rated input voltage (3-phase (3P)) 380Vac-500Vac - Rated output current 87A (Low overload IL) - Rated power 45kW (Low overload IL; 400Vac; 50Hz) / 60HP (Low overload IL; 460V; 60Hz) - Frame size FR4 - IP21 - with EMC filter category C2 + DC choke - with Ethernet/IP / Modbus TCP / Modbus RTU / BACnet communication capability - with conformal coated PCB
Specifications
Primary brand
Eaton
Secondary brand
Cutler-Hammer
Main function
Variable Speed / Frequency Drive (VSD/VFD) / Inverter
Product series / family name
PowerXL
Sub-range name
DG1
Network frequency
(input) 45-66 Hz
(output) 0-400 Hz
(output) 0-400 Hz
Functions
Adjustable Variable Speed / Frequency Drive (AFD/VSD/VFD) / Inverter
Supply voltage (AC)
380Vac-500Vac
Type of network
3-phase input (3P)
Rated current
87A (Low overload IL)
72A (High overload IH)
72A (High overload IH)
Rated active power (kW)
45kW (Low overload IL; 400Vac; 50Hz)
37kW (High overload IH; 400Vac; 50Hz)
37kW (High overload IH; 400Vac; 50Hz)
Rated power (HP)
60HP (Low overload IL; 460V; 60Hz)
50HP (High overload IH; 460V; 60Hz)
50HP (High overload IH; 460V; 60Hz)
Protection functions
Overvoltage
Undervoltage
Earth fault
Input phase supervision
Motor phase supervision
Overcurrent
Unit overtemperature
Motor overload
Motor stall
Motor underload
DC bus overvoltage control
Short-circuit
Surge protection
Undervoltage
Earth fault
Input phase supervision
Motor phase supervision
Overcurrent
Unit overtemperature
Motor overload
Motor stall
Motor underload
DC bus overvoltage control
Short-circuit
Surge protection
Communication protocol
Ethernet/IP
Modbus TCP
Modbus RTU
BACnet
Modbus TCP
Modbus RTU
BACnet
Net Width (mm)
237.7 mm
Net Depth (mm)
629.9 mm
294 mm
294 mm
Operating mode
Frequency control
Speed control
Open-loop speed control
Open-loop torque control
Speed control
Open-loop speed control
Open-loop torque control
Digital inputs
1 x digital input (FWD)
1 x digital input (REV)
1 x digital input (external fault)
1 x digital input (fault reset)
1 x digital input (preset speed B0)
1 x digital input (preset speed B1)
1 x digital input
1 x digital input (force remote TI+)
1 x digital input (REV)
1 x digital input (external fault)
1 x digital input (fault reset)
1 x digital input (preset speed B0)
1 x digital input (preset speed B1)
1 x digital input
1 x digital input (force remote TI+)
Digital outputs
1 x digital output (Ready)
2 x digital outputs (SPDT Single Pole Double Throw contact type)
1 x digital output (NO contact type)
2 x digital outputs (SPDT Single Pole Double Throw contact type)
1 x digital output (NO contact type)
Analog inputs
1 x analog input (0-10V DC)
1 x analog input (4-20mA)
1 x analog input (4-20mA)
Analog outputs
1 x analog output (Output Frequency; 4-20mA)
1 x analog output (Motor Current; 4-20mA)
1 x analog output (Motor Current; 4-20mA)
Degree of protection
IP21
Ambient air temperature for operation
-10...+50 °C
Ambient air temperature for storage
-40...+70 °C
Chemical resistance
conformal coated PCB
Technology used in component
EMC filter category C2
DC choke
DC choke
Display
LCD
Application type
General-purpose drive
Manufacturer product status
Commercialized
Compliant with standard(s)
IEC/EN 61800-5-1
IEC/EN 61800-5-2
UL 508C
IEC 61508
EN 62061
EN ISO 13849-1
IEC/EN 61800-3
UL
cUL
CE
C-Tick
RoHS
EAC
Plenum rated
IEC/EN 61800-5-2
UL 508C
IEC 61508
EN 62061
EN ISO 13849-1
IEC/EN 61800-3
UL
cUL
CE
C-Tick
RoHS
EAC
Plenum rated
Benefits
Integrated common mode reduction 5% DC link choke with input surge protection
Real-time clock supports calendaring and PLC functionality
Graphic LCD display and keypad supports simple menu navigation as well as on-screen diagnostics and troubleshooting
LOCAL/REMOTE operation from keypad and two configurable soft keys
Control logic can be powered from an external auxiliary control panel; internal drive functions and fieldbus if necessary
Seamless integration into Ethernet/IP networks via EIP-Assist I/O tag-generation tool
Two expansion slots intended to support additional I/O or communication protocols as necessary
Quick disconnect terminals for I/O connections supports fast easy installation
Safe Torque Off (STO) built in with functional safety SIL1 certification
Real-time clock supports calendaring and PLC functionality
Graphic LCD display and keypad supports simple menu navigation as well as on-screen diagnostics and troubleshooting
LOCAL/REMOTE operation from keypad and two configurable soft keys
Control logic can be powered from an external auxiliary control panel; internal drive functions and fieldbus if necessary
Seamless integration into Ethernet/IP networks via EIP-Assist I/O tag-generation tool
Two expansion slots intended to support additional I/O or communication protocols as necessary
Quick disconnect terminals for I/O connections supports fast easy installation
Safe Torque Off (STO) built in with functional safety SIL1 certification
Net weight
35.2 kg
Degree of pollution
2